反渗透运行影响因素分析与调整对策
引用本文:叶光华. 反渗透运行影响因素分析与调整对策[J]. 净水技术, 2002, 21(2): 31-33,40
作者姓名:叶光华
作者单位:山东淄博嘉周热电有限公司,山东淄博,255300
摘    要:本文对淄博嘉周热电有限公司反渗透系统运行中因水源的变化、预处理工艺过于简单、设备上的缺陷、药剂影响等造成的渗透膜污堵快 ,清洗频繁等而严重影响安全运行的原因进行了分析 ,采取了调整措施 ,确保了反渗透的安全稳定运行 ,取得了优异成效

关 键 词:反渗透  运行调整  对策  膜污堵

Analysis of Related Factors in Operation of RO-System and Regulation Countermeasures
Yi Guanghua. Analysis of Related Factors in Operation of RO-System and Regulation Countermeasures[J]. Water Purifcation Technology, 2002, 21(2): 31-33,40
Authors:Yi Guanghua
Abstract:In this paper author analyzed the variation of raw water quality, rough of pre-treatment processes and shortcomings of equipments in RO-system of Zibo Jiazhou and concluded that due to these factors, operation periods of RO-menbrane shortened, cleaning and washing conducted more frequently and thus safty in production damaged. After regulation countermeasures were taken, RO-system of this Co. was operated in good order.
Keywords:reverse osmosis operation regulation countermeasures menbrane fouling