首页 | 本学科首页   官方微博 | 高级检索  
     

运行条件变化对锅炉效率的修正
引用本文:杨志勇,刘引.运行条件变化对锅炉效率的修正[J].电站系统工程,2004,20(1):19-20.
作者姓名:杨志勇  刘引
作者单位:阜阳华润发电有限公司;哈尔滨锅炉厂有限责任公司
摘    要:针对HG-2008/17.4-YM锅炉叙述了锅炉性能试验时煤质、给水温度、空气温度等条件变化时如何向设计条件进行修正。给出了相应的修正曲线,修正到设计条件下的效率等于锅炉实际测量效率加上由曲线查出的效率修正值(Dh)。

关 键 词:锅炉效率  修正曲线  性能试验  变化
文章编号:1005-006X(2004)01-0019-02
修稿时间:2003年6月19日

Correction for Boiler Efficiency from Variation of Operation Condition
YANG Zhi-yong,LIU Yin.Correction for Boiler Efficiency from Variation of Operation Condition[J].Power System Engineering,2004,20(1):19-20.
Authors:YANG Zhi-yong  LIU Yin
Abstract:Aiming at 2008t/h boiler, it is presented that how such conditions as coal grade, feed-water temperature, air temperature are corrected to design condition when variation during boiler performance test. The relative correction curves are given. The efficiency corrected to that under design condition is boiler efficiency measured actually pluses the efficiency correction value found from curves.
Keywords:boiler efficiency  correction curve  performance test  variation