1000MW直流塔式超超临界锅炉水冷壁裂纹分析及处理
引用本文:唐豪毅,盛卫民.1000MW直流塔式超超临界锅炉水冷壁裂纹分析及处理[J].水利电力机械,2011(4):44-46.
作者姓名:唐豪毅  盛卫民
作者单位:浙江省火电建设公司,浙江杭州310006
摘    要:介绍了某电厂1000MW直流塔式超超临界锅炉T23钢水冷壁裂纹的类型及泄漏部位的结构,分析了裂纹产生原因,提出了有效的解决方案。

关 键 词:直流锅炉  水冷壁  裂纹  原因分析  处理措施

Analysis on cracks of water wall in 1000MW ultra-supercritical tower-type once-through boiler and treatment
TANG Haoyi,SHENG Weimin.Analysis on cracks of water wall in 1000MW ultra-supercritical tower-type once-through boiler and treatment[J].Water Conservancy & Electric Power Machinery,2011(4):44-46.
Authors:TANG Haoyi  SHENG Weimin
Affiliation:(Zhejiang Thermal Power Construction Company,Hangzhou 310006,China)
Abstract:The type of the cracks of water wall,the material of which is T23 steel,in 1000MW ultra-supercritical tower-type once-through boiler in a power plant was introduced;and the structure of leakage fault position was described.The reasons of the cracks were analyzed;and effective solution was put forward.
Keywords:once-through boiler  water wall  crack  reason analysis  treatment measure