摘    要:中国计量科学研究院自行研制的开口镓熔点装置实现了对镓熔点冻制及复现的自动化,建立了开口镓熔点配置标准铂电阻温度计组成的基准装置。实验结果显示:镓熔点熔化温坪长达50h,镓熔点的复现性为0.1mK,闭口结构与开口结构镓熔点量值差异经过气压修正后由0.13mK减小至0.06mK,镓熔点温度-气压线性拟合曲线所得数值与90温标中给出的镓熔点气压修正系数一致。

关 键 词:计量学  镓熔点  气压修正  开口型结构  国际温标
收稿时间:2020-09-08

Reproduction and Barometric Pressure Correction of Open Gallium Melting Point Device
MAO Ju-lin,SUN Jian-ping,LU Xiao-feng. Reproduction and Barometric Pressure Correction of Open Gallium Melting Point Device[J]. Acta Metrologica Sinica, 2021, 42(11): 1454-1458. DOI: 10.3969/j.issn.1000-1158.2021.11.07
Authors:MAO Ju-lin  SUN Jian-ping  LU Xiao-feng
Affiliation:1. Ningxia Academy of Metrological & Quality Inspection, Yinchuan, Ningxia 750200, China
2. National Institute of Metrology, Beijing 100029, China
Abstract:The open gallium melting point device developed by the National Institute of Metrology in China realized the freezing and reappearance automation of gallium melting point, and established a benchmark device composed of standard platinum resistance thermometers and open gallium melting point. The experimental results showed that the melting temperature plateau of gallium melting point lasted 50h, and the reproducibility of gallium melting point is 0.1mK, the difference between the closed structure and the open structure of gallium melting point container is reduced from 0.13mK to 0.06mK after air pressure correction,the value obtained from the gallium melting point temperature-pressure linear fitting curve is consistent with the correction coefficient of the gallium melting point given in the 90 temperature scale.
Keywords:metrology  melting point of gallium  barometric pressure correction  open-type structure  international temperature scale  