基金项目:国家自然科学基金(11505183);脉冲功率激光技术国家重点实验室开放基金(SKL2015KF05)
摘    要:针对锁模激光器微弱回波信号探测的需求,提出了一种基于高速相关采样和在线实时并行累加处理算法相结合的方法,对传统的模拟取样积分方法进行了改进,可实现无参考信号条件下的实时数字累加检测。设计并实现了一套基于该方法的锁模激光器微弱回波信号检测原型系统,使用12 bit@900 MSPS模拟-数字转换芯片(ADC) ADS5409对经光电转换之后的锁模激光回波信号进行波形采样,并利用现场可编程逻辑门阵列(FPGA)芯片Kintex-7实现对ADC的控制及在线数据处理。系统测试结果表明,对于重复频率为8 MHz、平均功率为0.04 nW的锁模激光回波信号,通过在FPGA内进行16 000次脉冲波形精确累加,可实现信号的有效检出,且从波形采集完毕到输出检测结果的延时小于100 ns,达到了高度的实时性。经900次重复实验,检测效率达到100%,且无虚警情况发生。

关 键 词:微弱信号检测   锁模激光器   相关采样   ADC   FPGA
收稿时间:2017-04-12

Real-time detection of mod-locked laser echo signal based on high-speed correlation sampling
Affiliation:1.State Key Laboratory of Particle Detection and Electronics,University of Science and Technology of China,Hefei 230026,China;2.State Key Laboratory of Pulsed Power Laser Technology,Electronic Engineering Institute,Hefei 230037,China
Abstract:According to the demands of mod-locked laser weak echo signal detection, a method which combined high-speed correlation sampling and parallel accumulation based on Field-Programmable Gate Array (FPGA) was proposed. This method overcame the shortcomings of the traditional sampling integral algorithm and can work real-timely without reference signal. Besides, a mod-locked laser weak echo signal detection system based on this method was designed and implemented. This system mainly consisted of a 12 bit@900 MSPS Analog-to-Digital Converter(ADC) chip, ADS5409, which sampled the echo signal and a FPGA chip, Kintex-7, which was in charge of controlling and on-line calculation. To the signal with the repetition frequency of 8 MHz and the average power of 0.04 nW, by accumulation of 16 000 pulses, this system can realize efficient detection and the calculation latency is shorter than 100 ns. In 900 experiments, the correct rate of the detection system reaches as high as 100% without false alarm.
Keywords:
点击此处可从《红外与激光工程》浏览原始摘要信息
点击此处可从《红外与激光工程》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号