首页 | 本学科首页   官方微博 | 高级检索  
     

面向扰动的多尺度交直流混联电压校正策略
引用本文:葛惠阳,王彬,孙宏斌,符杨,夏天,王玮. 面向扰动的多尺度交直流混联电压校正策略[J]. 电力系统自动化, 2018, 42(20): 102-108
作者姓名:葛惠阳  王彬  孙宏斌  符杨  夏天  王玮
作者单位:上海电力学院电气工程学院;清华大学电机工程与应用电子技术系;国网甘肃省电力公司
基金项目:国家电网公司科技项目“国分省互动的特高压近区电网无功电压控制研究与应用”
摘    要:目前,中国电网已建成多个交直流混联系统,运行中遇到的扰动带来的电压安全问题备受关注。传统电压校正控制受限于调控能力及响应速度,无法应对所有扰动。因此,文中提出运用直流系统的调控能力对越限电压进行校正。首先,基于不同动作方式及扰动的特性,分多尺度建立交直流系统电压域优化模型,作为电压校正控制的基础。其次,针对不同尺度的电压安全域建立了电压校正控制模型,以最小动作代价为目标,保证系统电压在正常情况下和N-1故障后均能满足安全性要求。最后,以某实际系统为模型进行仿真验证,证明了该方法的可行性与有效性。

关 键 词:交直流混联系统;多尺度;N-1安全性;电压安全域;电压校正控制
收稿时间:2017-08-28
修稿时间:2018-09-11

Correction Strategy of Multi-scale AC/DC Hybrid Voltage for Disturbance
GE Huiyang,WANG Bin,SUN Hongbin,FU Yang,XIA Tian and WANG Wei. Correction Strategy of Multi-scale AC/DC Hybrid Voltage for Disturbance[J]. Automation of Electric Power Systems, 2018, 42(20): 102-108
Authors:GE Huiyang  WANG Bin  SUN Hongbin  FU Yang  XIA Tian  WANG Wei
Affiliation:College of Electric Power Engineering, Shanghai University of Electric Power, Shanghai 200090, China,Department of Electrical Engineering, Tsinghua University, Beijing 100084, China,Department of Electrical Engineering, Tsinghua University, Beijing 100084, China,College of Electric Power Engineering, Shanghai University of Electric Power, Shanghai 200090, China,Department of Electrical Engineering, Tsinghua University, Beijing 100084, China and State Grid Gansu Electric Power Company, Lanzhou 730050, China
Abstract:Now, China has built many AC/DC hybrid systems. The disturbance in operation which causes voltage security problem has been highly concerned. Due to the limits of control ability and responding time, the traditional voltage correction control cannot deal with all the disturbance. Thus, regulation ability of DC system is used to correct over-limited voltage. Firstly, this paper sets up voltage security region optimization model of multi-scale AC/DC system, as the base of voltage correction control according to the different action modes and the characteristics of disturbances. Then, aiming at different scales of security region, this paper sets up voltage correction control optimization model to maintain the voltage within the security region under both normal condition and N-1 contingency. Finally, the feasibility and effectiveness of the method are proved by simulating a real system model.
Keywords:AC/DC hybrid system   multi-scale   N-1 security   voltage security region   voltage correction control
本文献已被 CNKI 等数据库收录!
点击此处可从《电力系统自动化》浏览原始摘要信息
点击此处可从《电力系统自动化》下载全文