首页 | 本学科首页   官方微博 | 高级检索  
     


Validating a MCNPX model of Mg(Ar) and TE(TE) ionisation chambers exposed to 60CO gamma rays
Authors:Roca A  Nievaart V A  Moss R L  Stecher-Rasmussen F  Zamfir N V
Affiliation:High Flux Reactor, Institute for Energy, Joint Research Centre, European Commission, Petten, The Netherlands. antoaneta.roca@jrc.nl
Abstract:For an accurate determination of the absorbed doses in complex radiation fields (e.g. mixed neutron-gamma fields), a better interpretation of the response of ionisation chambers is required. This study investigates a model of the ionisation chambers using a different approach, analysing the collected charge per minute as a response of the detector instead of the dose. The MCNPX Monte Carlo code is used. In this paper, the model is validated using a well-known irradiation field only: a (60)Co source. The detailed MCNPX models of a Mg(Ar) and TE(TE) ionisation chamber is investigated comparing the measured charge per minute obtained free-in-air and in a water phantom with the simulated results. The difference between the calculations and the measurements for the TE(TE) chamber is within +/-2% whereas for the Mg(Ar) chamber is around +7%. The systematic discrepancy in the case of Mg(Ar) chamber is expected to be caused by an overestimation of the sensitive volume.
Keywords:
本文献已被 PubMed Oxford 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号