摘    要:介绍了程控机房的热工环境要求,使用DeST模拟软件对程控机房的能耗进行了能耗模拟,根据闭式冷却塔应用原理和控制技术,提出程控机房空调系统的节能改造方案,以及改造系统的运行条件和防结冰措施,并对改造系统进行了经济性分析。

关 键 词:程控机房  闭式冷却塔  节能改造  空调系统

Study on the Technology of Energy Saving by Closed Cooling Tower to Cool SPC Exchanger Room
LI Zhi-tong,AI Yue-ping,ZHANG Ji-li.Study on the Technology of Energy Saving by Closed Cooling Tower to Cool SPC Exchanger Room[J].Refrigeration Air Conditioning & Electric Power Machinery,2010,31(5):24-27,23.
Authors:LI Zhi-tong  AI Yue-ping  ZHANG Ji-li
Affiliation:1.Zhejiang Electric Power Institute,Hangzhou 310012,China;2.Dalian University of technology,Dalian 116024,China)
Abstract:The characteristics and the request of SPC exchanger room were introduced.The energy consumption of SPC exchanger room was simulated by using DeST.And according to the application principle of the closed cooling tower and control technolegy,an modified air-conditioning system which was more suitable to SPC exchanger room was put forward,also the operation condition and ice proof measurement for the modified system.Then the economic of the modified system was analyzed.
Keywords:SPC exchanger room  closed cooling tower  energy saving innovation  air-conditioning system