首页 | 本学科首页   官方微博 | 高级检索  
     


Heat transfer performance evaluation of one-stream heat exchangers and one-stream heat exchanger networks
Abstract:One-stream heat exchangers and one-stream heat exchanger networks are widely used in engineering. In this paper, the heat transfer performance evaluation of one-stream heat exchangers and one-stream heat exchanger networks is analyzed with the concepts of entropy generation rate, entropy generation number, revised entropy generation number, entropy resistance, entransy dissipation rate, entransy dissipation number and generalized thermal resistance. For the analyzed one-stream heat exchangers, our numerical results show that the extremum value of the entransy dissipation rate and the minimum values of the entropy resistance and the generalized thermal resistance always lead to the largest heat transfer rate or the lowest temperature of the cooled object,while the minimum values of the other parameters do not always. For the analyzed one-stream heat exchanger networks, the minimizations of entransy dissipation rate, entransy dissipation number and generalized thermal resistance always correspond to the lowest average temperature of the cooled objects, while the minimizations of the other parameters do not. Therefore, only the extremum entransy dissipation principle and the minimum generalized thermal resistance principle are always applicable for the heat transfer performance evaluation of the systems in this paper, while the applicability of the other parameters is conditional.
Keywords:
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号