摘    要:张家口发电厂5号锅炉改造摆动燃烧器,通过实验建模的方法得出了摆动燃烧器调节再热汽温的对象特性,同时还介绍了该系统的控制策略和现场控制系统,并运用MATLAB软件对控制参数进行了优化。

关 键 词:摆动燃烧器  试验模型  智能定位器
文章编号:CN23-1249(2004)04-0029-02
修稿时间:2004-07-10

Improvement on the Control System for Homemade 300 MW Unit''''s Tilting Burner
QI Junhu,WU Junping,SHEN Guoqing. Improvement on the Control System for Homemade 300 MW Unit''''s Tilting Burner[J]. Boiler Manufacturing, 2004, 0(4): 29-31
Authors:QI Junhu  WU Junping  SHEN Guoqing
Affiliation:QI Junhu~1,WU Junping~2,SHEN Guoqing~3
Abstract:An engineering alteration of the titling burner control system is described in this paper, which is applied on the #5 boiler in Zhangjiakou Power Plant. The property of the reheated steam regulated by tilting burner is achieved on testing model. At the same time the system's control poliay and the field control are introduced here, and the MATLAB is also applied to optimize the PID parameter.
Keywords:tilting burner  testing model  SIP ART PS2 Electropneumatic Positioner