首页 | 本学科首页   官方微博 | 高级检索  
     

数字化微喷射用玻璃基组合微喷嘴设计及实验
引用本文:杨眉,朱丽,侯丽雅,章维一. 数字化微喷射用玻璃基组合微喷嘴设计及实验[J]. 光学精密工程, 2012, 20(7): 1580-1586
作者姓名:杨眉  朱丽  侯丽雅  章维一
作者单位:南京理工大学机械工程学院,江苏南京,210094
基金项目:国家自然科学基金,教育部博士学科点专项科研基金
摘    要:为提高液滴微喷射的喷效率和粉体微喷射的喷射方向性,选用普通硼硅酸盐毛细管和石英玻璃管为原材料,基于稳定的拉制和锻制工艺,设计并制作了直列式组合微喷嘴和同轴式组合微喷嘴.在基于微流体数字化的微喷射实验平台上,利用4×2直列式组合微喷嘴单次喷射得到了形状规则、圆整,大小均匀,无卫星液滴的液滴阵列,液滴平均直径为180 μm;相对于单微喷嘴,直列式组合喷嘴提高了单次微喷射的效率.另外,进行了粉体微喷射实验,相对于单微喷嘴,同轴式组合微喷嘴在相同驱动条件下,出射角由33°减小至10°,成形粉线的宽度由450 μm降低至300 μm.结果表明,同轴式组合微喷嘴中的辅助喷嘴有效地约束了主喷嘴出射的粉体流动,粉体喷射的方向性有显著提高.

关 键 词:微流体数字化  微喷射  玻璃基  组合微喷嘴
收稿时间:2012-01-28

Design and experiment of vitreous combined micro nozzles used in digital micro injection
YANG Mei , ZHU Li , HOU Li-ya , ZHANG Wei-yi. Design and experiment of vitreous combined micro nozzles used in digital micro injection[J]. Optics and Precision Engineering, 2012, 20(7): 1580-1586
Authors:YANG Mei    ZHU Li    HOU Li-ya    ZHANG Wei-yi
Affiliation:(School of Mechanical Engineering,Nanjing University of Science and Technology,Nanjing 210094,China)
Abstract:In order to improve the injection efficiency of liquid micro injection and the injection directivity of powder micro injection,a borosilicate capillary and a quartz glass tube are chosen as raw materials to design and manufacture the in-line combined micro nozzle and the coaxial combined micro nozzle based on stable drawing and forging process.Using these tow combined micro nozzles,liquid and powder micro injection experiments are performed on a micro injection experiment system based on the digitalization of microfluidic technology.In liquid micro injection experiment,the regular and uniform droplet array with a average diameter of 180 μm and no satellite droplets is prepared with one injection in a 4×2 in-line combined micro nozzle,by which the efficiency of micro injection under in-line combined micro nozzle is improved as compared with that of single micro nozzle.In powder micro injection experiment,the injection angle is reduced from 33° to 10° and the width of formed powder line is decreased from 450 μm to 300 μm as compared with that of single micro nozzle.The results indicate that the powder flow of the major micro nozzle in coaxial combined micro nozzle is constrained with the assisted micro nozzle and the injection directivity is improved greatly.
Keywords:digitalization of microfluidic  micro injection  vitreous  combined micro nozzle
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号