摘    要:为了保证智能变电站通讯网络运行的稳定性和安全性,提出了智能变电站通讯网络端口接入控制的安全策略。介绍了智能变电站的通讯方式和网络结构,分析了智能变电站存在的安全隐患和交换机的端口安全接入控制需求。解释了基于静态MAC地址的端口安全的工作原理和技术特点,阐述了基于IEEE802.1X协议的端口安全的组网方式、工作原理、认证过程和技术特点,总结了现阶段智能变电站端口安全策略的具体应用模式和实施方案。最后得出结论,现阶段采用静态MAC地址和IEEE802.1X相结合的方式进行交换机的端口安全接入控制可以兼顾有效性和可行性,具有实用价值。

关 键 词:智能变电站  交换机  端口安全  端口接入控制  静态MAC  IEEE.X
收稿时间:2013/9/30 0:00:00
修稿时间:2013/12/26 0:00:00

Research on application of switch port access control in smart substation
GAO Ji-pu,XU Chang-bao,DAI Yu,WU Jie and ZHANG Dao-nong.Research on application of switch port access control in smart substation[J].Power System Protection and Control,2014,42(13):117-122.
Authors:GAO Ji-pu  XU Chang-bao  DAI Yu  WU Jie and ZHANG Dao-nong
Affiliation:Guizhou Electric Power Research Institute, Guiyang 550002, China;Guizhou Electric Power Research Institute, Guiyang 550002, China;Guizhou Electric Power Research Institute, Guiyang 550002, China;Nanjing Youkuo Electric Co., Ltd, Nanjing 211100, China;Huabei Electric Designation Institute, Beijing 100000, China
Abstract:To ensure the stability and security of the communication network of the smart substation, the switch port access control strategy of the communication network in the smart substation is put forward. The smart substation communication mode and network structure are introduced, the potential safety hazard and the switch port access control requirements of smart substation are analyzed. The theory and technical characteristics of the port security based on static MAC address are explained, and the networking mode, theory, authentication process and technical characteristics of the port security based on IEEE802.1X protocol are elaborated. The application cases and implementation schemes of port security strategy during the present time in smart substation are concluded. In conclusion, to control the switch port security of the smart substation, the strategy combining with the static MAC address and IEEE802.1X protocol is valid, feasible and practical at present.
Keywords:smart substation  switch  port security  port access control  static MAC  IEEE802  1X
本文献已被 CNKI 等数据库收录!
点击此处可从《电力系统保护与控制》浏览原始摘要信息
点击此处可从《电力系统保护与控制》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号