首页 | 本学科首页   官方微博 | 高级检索  
     

韶钢90 t电炉Consteel水冷件漏水故障分析及对策
引用本文:石文,毛永华.韶钢90 t电炉Consteel水冷件漏水故障分析及对策[J].南方钢铁,2013(6):18-20.
作者姓名:石文  毛永华
作者单位:宝钢集团广东韶关钢铁有限公司,广东韶关512123
摘    要:2005年,炼轧厂对90t Consteel电炉进行工艺改造后,由于冶炼时吹氧强度的加大,炉内反应剧烈等因素影响,电炉水冷件漏水成为制约炼钢生产的重要原因.通过对水冷件漏水现象的跟踪、分析,决定改进设备的水冷方式与结构,以及新型材质的使用,使得水冷件漏水现象得到较好的控制,炼钢生产产能得到释放,技经指标不断优化.

关 键 词:Consteel电炉  水冷件  漏水

Analysis on Leakages in 90t Consteel EAF Water-cooling Parts at SGIS and Its Countermeasures
Affiliation:SHI Wen, MAO Yong- hua ( Baosteel Group Guangdong Shaoguan Iron & Steel Co. , Ltd. , Shaoguan, Guangdong, 512123, P.R. China)
Abstract:Since 2005, the steel making & iron rolling plant have completed the process modification for 90 t Consteel elec- tric arc furnace. The leakage of its water - cooling parts has become a bottleneck which restricts the steelmaking for oxygen smelting intensity increases and violent reactions in the furnace and other factors exist. After tracking and analyzing the wa- ter leakage phenomenon in the water - cooling parts, water - cooling and structures of the equipment have been improved, as well as new materials have been used, which make the leakages of water - cooling parts get better control, steel produc- tion capacity be released, and technology and economic indicators continue to be optimized.
Keywords:Consteel electric arc furnace  water- cooling parts  leakage
本文献已被 维普 等数据库收录!