摘    要:简要地介绍了离心式冷水机组采用变频器拖动节能改造的原理及特性,并通过应用实例在生产过程中的实际运行检测数据来说明开利离心式冷水机组改用变频器拖动后的节能效果和提高机组运行的可靠性和优点。

关 键 词:离心式冷水机组  变频器  节能

The inverter drive energy-saving modification of centrifugal water chiller
HE Ji-you. The inverter drive energy-saving modification of centrifugal water chiller[J]. Polyester Industry, 2011, 24(1): 54-56. DOI: 10.3969/j.issn.1008-8261.2011.01.016
Authors:HE Ji-you
Affiliation:HE Ji-you(Guangdong Kaiping Chunhui Co.Ltd.,Kaiping 529300,China)
Abstract:The inverter drive energy-saving modification principles and characteristics of the centrifugal water chiller were introduced.The actual operation detection data of the application example in the production process was used to explain the energy-saving efficiency after modification.The reliability and advantages of the water chiller were improved.