首页 | 本学科首页   官方微博 | 高级检索  
     


Technical note: Flow cytometric identification of bovine milk neutrophils and simultaneous quantification of their viability
Authors:S. Piepers  S. De Vliegher  B.N. Lambrecht  E. Meyer
Affiliation:* Department of Reproduction, Obstetrics, and Herd Health, Faculty of Veterinary Medicine, Ghent University, 9820 Merelbeke, Belgium
Department of Pharmacology, Toxicology, Biochemistry, and Organ Physiology, Laboratory of Biochemistry, Faculty of Veterinary Medicine, Ghent University, 9820 Merelbeke, Belgium
Department of Internal Medicine subdivision Pneumology, Faculty of Medicine and Health Sciences, Ghent University, 9000 Ghent, Belgium
Abstract:The aim of the present study was to develop a flow cytometric procedure for the quantification of the proportion of viable, apoptotic, and necrotic polymorphonuclear neutrophilic leukocytes (PMNL) isolated from both low- and high-somatic-cell-count quarter milk samples. Milk PMNL were differentiated from other cells by indirect fluorescent labeling using a primary anti-bovine granulocyte monoclonal antibody (CH138A) and an Alexa 647-labeled secondary antibody. Polymorphonuclear neutrophilic leukocytes were identified flow cytometrically based on their cytoplasmic granularity and CH138A-positivity. Additional labeling with annexin-V-fluorescein isothiocyanate and propidium iodide was used to determine milk PMNL viability. Thirty milk samples were run in parallel to assess the repeatability of the immunoassay and 6 repeated measurements per sample were performed to assess the instrument stability. Fluorescence microscopic verification of the CH138A staining pattern showed both a high sensitivity (90.9%) and specificity (92.3%). The combination of the side-scatter properties of granulated PMNL and CH138A-Alexa 647 positivity allows the distinction of labeled PMNL from other milk cells and particles that may bind nonspecifically, and from autofluorescent particles present in milk. Quantification of the proportion of PMNL and viable, apoptotic, and necrotic subpopulations in parallel samples gave repeatable results with concordance correlation coefficients varying between 0.93 and 0.99. The average coefficient of variation for repeated measurements in identical samples ranged between 4.2 and 9.7%. In conclusion, this is the first flow cytometric method suited for the simultaneous quantification of viable, apoptotic, and necrotic bovine milk PMNL in a straightforward manner.
Keywords:bovine   flow cytometry   milk   neutrophil
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏