首页 | 本学科首页   官方微博 | 高级检索  
     


Hydration abnormalities in Nigerian patients on chronic hemodialysis
Authors:Tzamaloukas Antonios H  Onime Aideloje  Agaba Emmanuel I  Vanderjagt Dorothy J  Ma Irene  Lopez Andrea  Tzamaloukas Rolinda A  Glew Robert H
Affiliation:Department of Medicine Service, New Mexico Veterans Affairs Health Care System and University of New Mexico School of Medicine, Albuquerque, NM 87108, USA. antonios.tzamaloukas@med.va.gov
Abstract:The state of hydration affects the outcomes of chronic dialysis. Bioelectrical impedance analysis (BIA) provides estimates of body water (V), extracellular volume (ECFV), and fat-free mass (FFM) that allow characterization of hydration. We compared single-frequency BIA measurements before and after 14 hemodialysis sessions in 10 Nigerian patients (6 men, 4 women; 44+/-7 years old) with clinical evaluation (weight removed during dialysis, presence of edema) and with estimates of body water obtained by the Watson, Chertow, and Chumlea anthropometric formulas. Predialysis and postdialysis values of body water did not differ between BIA and anthropometric estimates. However, only the BIA estimate of the change in body water during dialysis (-0.8+/-2.9 L) did not differ from the corresponding change in body weight (-1.3+/-3.0 kg), while anthropometric estimates of the change in body water were significantly lower, approximately one-third of the change in weight. Bioelectrical impedance analysis correctly detected the intradialytic change in body water content (the ratio V/Weight) in 79% of the cases, while anthropometric formula estimates of the same change were erroneous in each case. Compared with patients with clinical postdialysis euvolemia (n=7), those with postdialysis edema (n=5) had higher values of postdialysis BIA ratios V/FFM (0.77+/-0.01 vs. 0.72+/-0.03, p<0.01) and ECFV/V (0.53+/-0.02 vs. 0.47+/-0.06, p<0.05), respectively. Bioelectrical impedance analysis appeared to underestimate body water and extracellular volume in a patient with massive ascites and bilateral pleural effusions. Anthropometric formulas are not appropriate for evaluating the state of hydration in patients on chronic hemodialysis. In contrast, BIA provides estimates of hydration agreeing with clinical estimates in the same patients, although it tends to underestimate body water and extracellular volume in patients with large collections of fluid in central body cavities.
Keywords:Body water  extracellular volume  hemodialysis  bioimpedance  anthropometry  Nigeria
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号