首页 | 本学科首页   官方微博 | 高级检索  
     

风机盘管加新风系统室内PM2.5污染控制
引用本文:樊越胜,谢伟,余俊伟,司鹏飞.风机盘管加新风系统室内PM2.5污染控制[J].土木建筑与环境工程,2017,39(6):111-116.
作者姓名:樊越胜  谢伟  余俊伟  司鹏飞
作者单位:1. 西安建筑科技大学环境与市政工程学院,西安,710055;2. 中国建筑西南设计研究院,成都,610042
基金项目:“十三五”国家重点研发计划,13th Five-Year Key Project
摘    要:在对民用建筑通风系统常用过滤器滤料性能测试基础上,建立了常规风机盘管加新风系统空调房间室内颗粒物浓度集总参数模型,讨论了回风过滤段和新风过滤段过滤器效率的设计选型方法。以西安市某空调系统为例,为满足室内PM2.5污染控制标准,基于室外PM2.5浓度"不保证10d"取值计算,结果表明,余压为50~80Pa的机组回风过滤器效率选用G3、G4型过滤器,余压为30~50Pa的机组回风过滤器效率选用初效G2、G3型过滤器,同时,室内设置等效过滤效率的空气净化器,新风选用初效G4加中效F7或F8两级过滤。

关 键 词:新风系统  风机盘管  PM2.5  空气过滤器
收稿时间:2016/11/29 0:00:00

Pollution control of indoor PM2.5 of fan coil unit and fresh air system
Fan Yuesheng,Xie Wei,Yu Junwei and Si Pengfei.Pollution control of indoor PM2.5 of fan coil unit and fresh air system[J].土木建筑与环境工程,2017,39(6):111-116.
Authors:Fan Yuesheng  Xie Wei  Yu Junwei and Si Pengfei
Affiliation:School of Environmental and Municipal Engineering, Xi''an University of Architecture and Technology, Xi''an 710055, P. R. China,School of Environmental and Municipal Engineering, Xi''an University of Architecture and Technology, Xi''an 710055, P. R. China,School of Environmental and Municipal Engineering, Xi''an University of Architecture and Technology, Xi''an 710055, P. R. China and China Southwest Architecture Design Institute, Chengdu 610042, P. R. China
Abstract:A theoretical and experimental measurement analysis on air filter of fan coil unit and fresh air system was conducted through establishing a mass balance equation.In this paper,a certain building in Xi'an is taken as an example,the outdoor PM2.5 concentration is calculated based on "no assurance of 10 days".The results show that the synthetic fiber of G3 or G4 air filter can be used in return air of FCU when the fan pressure is 50-80pa,and the G2 or G3 air filter can be used when the pressure is 30-50pa.Meanwhile,G4 and F7 or F8 two-stage filtration can be used in fresh air system when equivalent filtration efficiency air purifier should be installed.
Keywords:primary air system  FCU  PM2  5  air filter
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《土木建筑与环境工程》浏览原始摘要信息
点击此处可从《土木建筑与环境工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号