摘    要:结合天津一个空调面积为14000m^2的地埋管地源热泵空调工程的设计,介绍对地埋管换热器的取热量和散热量进行测试的实验方法,为工程设计提供可靠的依据。对天津地区不加防冻液地埋管地源热泵机组进行讨论,并分析热泵机组采用满液式蒸发器,节能效果更加明显。

关 键 词:地埋管地源热泵  满液式蒸发器  防冻液
修稿时间:2007-04-11

The perspective of several design problems of closed-loop ground source heat pump system
Zhang Yanli,Zhang Xinfa,You Shijun.The perspective of several design problems of closed-loop ground source heat pump system[J].Refrigeration and Air-conditioning,2007,7(5):74-77.
Authors:Zhang Yanli  Zhang Xinfa  You Shijun
Affiliation:1.Tianjin Zhongleng Heating Ventilation and Cleaning Project Technique Co. , Ltd. ; 2.Tianjin University
Abstract:Combined with a design of closed-loop ground source heat pump system used in a factory with 14 000 m^2 air-conditioning building, presents the design method by means of testing heat exchanger to measure the ability of receiving and removing heat from soil. According to the test data, the number of hole can be determined exacdy in design of project. Discusses closed-loop ground source heat pump without antifreeze used in Tianjin and heat pump with flooded evaporator, energy saving of the system is obviously.