首页 | 本学科首页   官方微博 | 高级检索  
     

理论模拟和实验对照研究幅值扫描ac对离子阱质谱性能的影响
引用本文:王伟民,靳留雨,徐福兴,丁传凡. 理论模拟和实验对照研究幅值扫描ac对离子阱质谱性能的影响[J]. 质谱学报, 2021, 42(5): 942-950. DOI: 10.7538/zpxb.2021.0129
作者姓名:王伟民  靳留雨  徐福兴  丁传凡
作者单位:宁波大学,浙江省先进质谱技术与分子检测重点实验室,质谱技术与应用研究院,材料科学与化学工程学院,浙江 宁波315211
摘    要:随着离子阱质谱分析技术的广泛应用,离子阱共振激发过程的理论模拟和实验验证对于深入研究离子阱质谱性能具有重要的意义.常见的线性离子阱所使用的共振激发弹出电压ac(alternating current)的设置有两种方式:一种是设定1个很小的恒定值(如1 V0-p),另一种是设定为1个幅值扫描范围.然而,鲜有人对比研究这两...

关 键 词:离子阱质谱  共振激发  理论模拟

Effect of Amplitude-Scanning ac on the Performance of Ion Trap Mass Spectrometry
WANG Wei-min,JIN Liu-yu,XU Fu-xing,DING Chuan-fan. Effect of Amplitude-Scanning ac on the Performance of Ion Trap Mass Spectrometry[J]. Journal of Chinese Mass Spectrometry Society, 2021, 42(5): 942-950. DOI: 10.7538/zpxb.2021.0129
Authors:WANG Wei-min  JIN Liu-yu  XU Fu-xing  DING Chuan-fan
Affiliation:Zhejiang Provincial Key Laboratory of Advanced Mass Spectrometry Technology and Molecular Detection,Institute of Mass Spectrometry Technology and Application, School of Materials Science and Chemical Engineering, Ningbo University, Ningbo 315211, China
Abstract:With the wide application of ion trap mass spectrometry, the theoretical simulation and experimental verification of resonant ejection play an important role in improving the performance of ion trap mass spectrometry. There are two common ways to set the (alternating current) (ac) resonant voltage of ion trap, one is to set a small constant value like 1 V0-p, and the other is to set an amplitude-scanning range. However, few people has studied the influence of the amplitude-scanning setting of ac on the analytical performance of ion trap mass spectrometry, and no experimental result has been studied by theoretical simulation neither. In this work, based on a homemade miniaturized ion trap mass spectrometry platform with continuous atmospheric pressure interface, the effect of amplitude-scanning resonance on the performance of ion trap mass spectrometry was studied by theoretical simulation and experimental study using a nano electrospray ionization source, and reserpine was used as the research object. Firstly, the effects of constant ac resonant ejection and amplitude-scanning ac resonant ejection on the resolution and sensitivity of ion trap mass spectrometry were studied experimentally. The experimental results showed that amplitude-scanning resonant ac ejection could improve the resolution and sensitivity of ion trap mass spectrometry, SIMION showed that the amplitude-scanning ac resonant ejection could prevent the ions from being excited in advance compared with the constant ac resonant ejection subsequently. Finally, the application experiments of two kinds of ions, fentanyl and narcotine showed that the resolution of amplitude-scanning ac resonant ejection was more than 2 times higher than that of constant ac resonant ejection. In conclusion, the effect of amplitude-scanning ac on the performance of ion trap mass spectrometry was studied by theoretical simulation and experimental comparison, and the theoretical simulation method and related program of resonance excitation process of ion trap mass spectrometry were established, which laid a foundation for further study of more complex nonlinear resonance and other high-order motion in ion trap. At the same time, the conclusions also help to improve the analytical performance of ion trap mass spectrometry to a certain extent, and accelerate the instrument debugging process of ion trap mass spectrometry.
Keywords:ion trap mass spectrometry  resonance ejection  theoretical simulation  
点击此处可从《质谱学报》浏览原始摘要信息
点击此处可从《质谱学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号