首页 | 本学科首页   官方微博 | 高级检索  
     

用动态光散射现代谱估计法测量纳米颗粒
引用本文:杨晖,郑刚,王雅静. 用动态光散射现代谱估计法测量纳米颗粒[J]. 光学精密工程, 2010, 18(9): 1996-2001. DOI: 10.3788/OPE.20101809.1996
作者姓名:杨晖  郑刚  王雅静
作者单位:上海理工大学,光电信息与计算机工程学院,上海,200093;山东理工大学,电气与电子工程学院,山东,淄博,255049
基金项目:上海市科委纳米专项基金资助项目,上海理工大学博士科研启动基金,上海理工大学光电学院教师创新能力建设项目,上海市重点学科建设资助项目,上海市优秀青年教师科研专项基金 
摘    要:为了解决目前动态光散射软件信号分析法采用的自相关和功率谱估计存在分辨率和方差较低,以及能谱泄漏问题,提出了基于现代功率谱估计的动态光散射信号分析法。对该系统所采用的现代功率谱估计算法和测量系统进行了研究。首先,介绍了动态光散射测量法涉及的光子相关光谱理论和散射光谱估计理论。接着,描述了基于现代功率谱估计的动态散射光谱法,特别是其中阶数p的计算方法。然后,介绍了测量系统,包括硬件部分的光学系统和信号采集处理系统,软件部分的系统开发流程。最后,对粒径分别为30、50、100nm的乳胶球标准颗粒溶液(透光率为96%)进行了实验。实验结果表明:现代谱估计分析法的测量均值误差和重复性误差的平均值分别为1.88%和1.62%,满足国标要求的均值误差和重复性误差2%。

关 键 词:颗粒测量  动态光散射  现代功率谱估计  自相关函数
收稿时间:2009-12-08
修稿时间:2010-01-15

Measurement of nano-particles by dynamic light scattering based on spectral estimation
YANG Hui,ZHENG Gang,WANG Ya-jing. Measurement of nano-particles by dynamic light scattering based on spectral estimation[J]. Optics and Precision Engineering, 2010, 18(9): 1996-2001. DOI: 10.3788/OPE.20101809.1996
Authors:YANG Hui  ZHENG Gang  WANG Ya-jing
Affiliation:1. School of Optical-Electronical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China;;2. School of Electric and Electronic Engineering, Shandong University of Technology, Zibo 255049,China
Abstract:A new dynamic light scattering analysis method based on modern power spectral estimation was proposed to resolve problems on lower resolution and variance, and power spectrum leakage in the current dynamic light scattering software.The modern power spectrum estimation algorithm and measurement system were studied. Firstly, the photon correlation spectroscopic theory and the scattering spectrum estimation of dynamic light scattering measurement were introduced. Then, the dynamic scattering spectrum based on modern power spectrum estimation was descripted in detail, and the order of p was calculated particularly. Furthermore, the measurement system was described,in which the hardware components included optical systems and signal processing system and the software showed the development process. Finally, a experiment was carried out on the latex particle sample solution with the particle diameters of 30, 50, 100 nm and solution transmission of 96%. The results show that the average values of the measurement error and repeatability error are 1.88% and 1.62%, respectively,which can achieve the national standard that the measurement and repeatability errors should be less than 2%, respectively.
Keywords:particle size measurement  dynamic light scattering  modern spectral estimation  auto-correlaiton function
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《光学精密工程》浏览原始摘要信息