采用紧凑型旋风分离器的循环流化床锅炉调试要点分析
引用本文:邓雨生.采用紧凑型旋风分离器的循环流化床锅炉调试要点分析[J].广东电力,2009,22(8):68-71.
作者姓名:邓雨生
作者单位:茂名石化动力厂,广东,茂名525000
摘    要:对采用紧凑型旋风分离器的410t/h循环流化床锅炉(circulating fluidized bed boiler,CFBB)启动调试的关键过程——烘炉、冷态试验、热态排渣试验进行分析,分析结果表明:根据紧凑型CFBB的结构特点,采用电加热器加管式燃烧器的热烟气法烘炉,可取得优良的烘炉效果;炉膛布风板设计合理,能确保均匀的流化;选择性冷渣器按掺烧油页岩的劣质燃料设计,具有足够裕量的排渣能力。

关 键 词:循环流化床锅炉  烘炉  冷态试验  热态排渣试验

Commissioning Kernel Analysis of Circulating Fluidized Bed Boiler with Compact Cyclone Separator
DENG Yusheng.Commissioning Kernel Analysis of Circulating Fluidized Bed Boiler with Compact Cyclone Separator[J].Guangdong Electric Power,2009,22(8):68-71.
Authors:DENG Yusheng
Affiliation:DENG Yu-sheng (Maoming Petrochemical Power Plant, Maoming, Guangdong 525000, China)
Abstract:The key steps in startup commissioning of 410 t/h circulating fluidized bed boiler (CFBB) using compact cyclone separator are analyzed, which include drying-out, cold test and hot deslagging test. The analytical results show that according to the structural features of compact CFBB, the effect of drying-out with hot gas from electric heater and tubular burner is excellent; rationally designed furnace distributor plate can ensure even fluidization; selective slag cooler designed as per inferior fuel containing oil shale is of adequate deslagging margin.
Keywords:circulating fluidized bed boiler (CFBB)  drying-out  cold test  hot deslagging test