首页 | 本学科首页   官方微博 | 高级检索  
     


Design and analysis of multiple parallel-pass condensers
Authors:Liang Ye  Ming Wei Tong  Xin Zeng
Affiliation:aChongqing University, Chongqing, PR China;bAir International Thermal System R&D (Shanghai) Co., Ltd., Shanghai, PR China;cSouth Air International Co., Ltd., Chongqing, PR China
Abstract:This paper describes and analyzes a novel design of multiple parallel-pass (MPP) microchannel tube condenser and its applications to automotive A/C systems. A flow distributor concept is introduced in MPP condenser in order to enable parallel flow arrangement in adjacent flow paths. Throughout analysis of two-phase flow and heat transfer processes in MPP condenser, a two-phase zone enlargement technique is developed to enhance condensation heat transfer and reduce pressure drop. Visual observation indicates a more uniform refrigerant quality entering the next cooling pass can be achieved in MPP condenser because superheated vapor through a pass-through hole on flow distributor directly injects into the separated liquid–vapor zone in a header tube. Performance test results show MPP condenser is able to improve heat transfer rate as high as 9.5% while its refrigerant mass flow increases 13.34% when comparing to a benchmark PF condenser.
Keywords:Air condenser  Air conditioning  Automobile  Microchannel  Design  Improvement  Heat transferMots clé  s: Cndenseur à  air  Conditionnement d'air  Automobile  Microcanal  Conception  Amé  lioration  Transfert de chaleur
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号