THE DEPENDENCE ON CHEMICAL COMPOSITION OF THE CETANE QUALITY OF HYDROTREATED LIGHT CYCLE OIL |
| |
Authors: | William J Danaher Peter A Johnston |
| |
Affiliation: |
a Ampol Research Laboratory, Australia |
| |
Abstract: | The dependence of the cetane number of hydrotreated light cycle oil on chemical composition has been investigated. Cetane number was related to hydrogen content and aromaticity. The latter was determined by high performance liquid chromatography and also by carbon-13 n.m.r. spectroscopy. Specific correlations were developed in each case and a regression coefficient of 0.99 and a standard error of 1.25 were obtained for the best case. The usefulness of predicting cetane number from fuel composition is discussed. |
| |
Keywords: | |
本文献已被 InformaWorld 等数据库收录! |