高层建筑室内消火栓给水管道设计探讨
引用本文:吴杰生.高层建筑室内消火栓给水管道设计探讨[J].山西建筑,2003,29(5):141-142.
作者姓名:吴杰生
作者单位:山西省建筑设计研究院
摘    要:阐述了高层建筑室内消火栓给水管道和阀门市置成环状管网的设计特点。并结合室内消火栓系统用水量,分析了三种环网的适用条件,指出对于设计中的具体问题应根据规范,灵活解决。

关 键 词:环状给水管网  流速  充实水柱
文章编号:1009-6825(2003)05-0141-02
修稿时间:2003年1月25日

Discussion on water supply pipeline design of indoor fire hydrant for high-rise building
WU Jie-sheng.Discussion on water supply pipeline design of indoor fire hydrant for high-rise building[J].Shanxi Architecture,2003,29(5):141-142.
Authors:WU Jie-sheng
Abstract:Loop is one of the features of water supply pipeline of indoor fire hydrant in high-rise building, while the pipeline without valves did not form loop. In this paper combined with water consumption in indoor fire hydrant system the application scope and valve distribution of three types ring nets are analyzed. The design should be practical according to codes and actual situations.
Keywords:ring water supply pipeline  flow rate  the substantial water columns  