摘    要:天津军粮城电厂5号炉自投产至今,已累计运行10万h,近两年来,发生多次爆管。通过对高温过热器的改造,提高了设备的可靠性。

关 键 词:过热器  更换  改造
文章编号:1003-6954(2005)02-0032-01
修稿时间:2004-12-20

Reformation of High-temperature Superheater in Boiler
Ma Bosheng. Reformation of High-temperature Superheater in Boiler[J]. Sichuan Electric Power Technology, 2005, 28(2): 32-32
Authors:Ma Bosheng
Abstract:The operating time of boiler No.5 in Tianjin Jun Liangcheng Power Plant has added up to 100 thousand hours from it being put into service. In recent two years, tube bursting happened time after time, and now based on the reformation of high-temperature superheater, the reliability of the equipment has been enhanced.