首页 | 本学科首页   官方微博 | 高级检索  
     


Assessment of modified consecutive modal pushover analysis for estimating the seismic demands of tall buildings with dual system considering steel concentrically braced frames
Affiliation:1. Department of Civil, Construction and Environmental Engineering, IA State University, USA;2. Sharma & Associates, Inc., Countryside, IL, USA;3. Department of Earthquake and Structural Engineering, Gebze Technical University, Turkey;4. Bosphorus University, Istanbul, Turkey;1. Department of Civil, Construction and Environmental Engineering, Iowa State University, Ames, IA, USA;2. Sharma & Associates, Inc., Countryside, IL, USA;3. Department of Earthquake and Structural Engineering, Gebze Institute of Technology, Turkey;1. School of Civil Engineering, Vellore Institute of Technology, Vellore 632014, Tamil Nadu, India;2. National Institute of Technology Tiruchirappalli, 620015, Tamil Nadu, India
Abstract:According to the previous researches, conventional nonlinear static procedure (NSP), which is limited to single mode response, cannot predict the seismic demands of tall buildings with reliable accuracy. To estimate the seismic demands in upper stories for tall buildings the effects of higher modes should be included. In the recent years, developing traditional pushover analysis to consider the effects of higher modes conducted researchers to propose several methods, such as N2, MPA and MMPA procedures, that have a specific approach to estimate seismic demands of structures but the accuracy of them is doubtable for estimating of hinge plastic rotations. Recently consecutive modal pushover (CMP) procedure was proposed to consider the effects of higher modes with acceptable accuracy especially in prediction of hinge plastic rotations. The CMP procedure was limited to include two or three modes, and use of higher modes might cause some inaccuracy at results of upper stories. In CMP procedure, estimation of modal participating factors is important and choosing inadequate modes may cause large errors. In this paper some changes have been applied to the CMP procedure to improve accuracy of the results and the modified method is proposed and named modified consecutive modal pushover (MCMP) procedure. In this modified method the contribution of mode is used of effective modal participating mass ratio. The comparison of MCMP procedure to exact values derived by nonlinear response history analysis (NL-RHA) demonstrated the reliable predictions and it can overcome the limitations of traditional pushover analysis.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号