首页 | 本学科首页   官方微博 | 高级检索  
     


A New Fast-Response Current Control Scheme for Line-Controlled Converters
Authors:Hpltz   Joachim Schwellenberg   Ulrich
Affiliation:Laboratory for Electrical Machines and Drives, University of Bergische;
Abstract:The drawbacks of closed-loop current control for line- controlled converters are eliminated by generating close to optimal firing pulses in a feedforward channel. The steady-state and dynamic nonlinearities of the converter and the dc motor load are compensated. A standby closed-loopcurrent controller is activated only in the presence of disturbances. Experimental results show excellent dynamic performance at all operating points of a noncirculating current four quandrant drive.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号