摘    要:本文针对热泵空调系统在冬季低温工况下制热能力衰减问题,通过换热器设计优化,研发出基于喷射补气的余热回收型热泵空调系统,并进行了性能实验研究.结果表明:研制的准二级压缩电动客车热泵空调系统在低温条件下具有较好的制热性能.在环境温度为-20℃,车内温度为20℃,余热量为1.8 kW的制热工况下,相比于无余热回收工况,系统制...

关 键 词:热泵空调系统  余热回收  喷射补气  换热器
收稿时间:2021/7/13 0:00:00
修稿时间:2021/9/8 0:00:00

Heat Exchanger Optimization and Performance Test of Waste Heat Recovery Heat Pump for Electric Bus
Zhang Wenchao,Zou Huiming,Han Xinxin,Tang Mingsheng,Tian Changqing.Heat Exchanger Optimization and Performance Test of Waste Heat Recovery Heat Pump for Electric Bus[J].Journal of Refrigeration,2022,43(1):91-99.
Authors:Zhang Wenchao  Zou Huiming  Han Xinxin  Tang Mingsheng  Tian Changqing
Affiliation:(Merchant Marine College, Shanghai Maritime University, Shanghai, 201306, China;Key Laboratory of Science and Technology on Space Energy Conversion, Technical Institute of Physics and Chemistry, CAS, Beijing, 100190, China;Henan Polytechnic University, Jiaozuo, 454000, China)
Abstract:In this study, a heat pump air conditioning system with waste heat recovery was developed based on vapor injection, and the performance was investigated experimentally. The study aimed to address the problem of heating capacity attenuation of heat pump air conditioning systems at low temperatures in winter, through the optimization of heat exchanger design. The experimental results show that the quasi two-stage compression heat pump air conditioner for electric buses exhibits good heating performance at low temperatures. Compared with the same working conditions without waste heat recovery, the heating capacity and coefficient of performance (COP) of the system are improved by 33.15% and 9.94%, respectively, where the ambient temperature is -20 °C, the interior temperature is 20 °C, and the residual heat is 1.8 kW. Compared with the single-stage compression system without battery cooling, the cooling capacity and COP of the optimized electric bus heat pump air conditioning system are increased by 4.58% and 3.72%, respectively, where the ambient temperature is 35 °C, the interior temperature is 27 °C, and the cooling capacity of the battery is 2.0 kW.
Keywords:heat pump air conditioning  waste heat recovery  vapor injection  heat exchanger