Abstract: | The test described in this paper is part of an Electric Power Research Institute (EPRI) program (Research Program RP2172-2) to provide a test-verified analytical method of estimating capacities of concrete reactor containment buildings under internal overpressurization from postulated degraded core accidents.Phase 2 of the EPRI program, on which this paper is based, includes tests of five large-scale specimens with steel liner plates. The specimens represent structural elements of prestressed concrete containment buildings. Four full-scale square wall element specimens and one specimen representing the wall/basemat junction region were tested. This paper describes results of the wall/basemat junction region test.Results of this experimental work indicate that highly localized strains in the steel liner plate caused by internal overpressurization or other accident conditions can result in liner tearing and subsequent containment leakage. It appears that this liner tearing occurs in a controller manner. Extrapolating from these test results, leakage and depressurization is more likely to occur than global failure. |