首页 | 本学科首页   官方微博 | 高级检索  
     

房间量热计法用于测量小制冷(热)量空调器的探讨
引用本文:马南,金毅萍.房间量热计法用于测量小制冷(热)量空调器的探讨[J].制冷与空调(北京),2010,10(3):73-75.
作者姓名:马南  金毅萍
作者单位:浙江省检验检疫科学技术研究院 
摘    要:重点介绍利用房间量热计法进行小制冷(热)量空调器能力测试时,采用室内外侧同时通冷冻水方法的特点及不足之处,该方法与GB/T7725—2004中所规定方法的差异,以及2种测试方法在测量不确定度方面的分析。

关 键 词:房间量热计法  冷冻水  不确定度  测试  空调器

Discussion on the application of room-type calorimeter method to test air conditioner with low refrigeration(heating) capacity
Ma Nan Jin Yiping.Discussion on the application of room-type calorimeter method to test air conditioner with low refrigeration(heating) capacity[J].Refrigeration and Air-conditioning,2010,10(3):73-75.
Authors:Ma Nan Jin Yiping
Affiliation:Ma Nan Jin Yiping (Zhejiang Academy of Science and Technology for Inspection Quarantine)
Abstract:Introduces the characteristics and the demerit of the room-type calorimeter method used for air conditioner with low refrigeration(heating) capacity when chilled water runs through both inside and outside of the testing room, and the difference between this method and the method stipulated in GB/T 7725-2004, as well as the uncertainty analysis of two kinds of test methods.
Keywords:room-type calorimeter method  chilled water  uncertainty  experiment  air conditioner