地下柴油发电机室噪声综合治理 |
| |
引用本文: | 焦书祥.地下柴油发电机室噪声综合治理[J].工程设计与建设,1999(4). |
| |
作者姓名: | 焦书祥 |
| |
作者单位: | 长沙冶金设计研究院 |
| |
摘 要: | 为解决某地下柴油发电机引起的噪声污染,设计采用了消声、吸声、隔声的综合治理方案,经测试,综合治理后的环境噪声达到了环保要求
|
关 键 词: | 柴油发电机 噪声污染 综合治理 消声 吸声 |
Comprehensive treatment of noise inunderground diesel generator room |
| |
Authors: | Jiao Shuxiang |
| |
Affiliation: | Jiao Shuxiang |
| |
Abstract: | In order to solve the problem of noise pollution caused by underground diesel generator, the comprehensive treatment plan of silencing, absorbing and insulating of noise was adopted in the design. Through test, the comprehensive treated environment noise was controlled for requirement of environmental protection. |
| |
Keywords: | Diesel generatorNoise pollutionComprehensive treatment Silencing of noiseAbsorbing of noise |
本文献已被 CNKI 等数据库收录! |