摘    要:针对开关控制回路的特点 ,结合实际 ,分析微机保护、电磁型触点去分流保护防跳回路的构成 ,提出了解决具体工程中防跳回路异常问题的方案

关 键 词:变电站    开关    防跳回路
文章编号:1003-4897(2003)01-0072-02
修稿时间:2002年1月18日

Parameters supervision and operation management of 500 kV GIS substation,Shajiao B power station
CHEN Zheng,pei.Parameters supervision and operation management of 500 kV GIS substation,Shajiao B power station[J].Power System Protection and Control,2003,31(1):72-73,83.
Authors:CHEN Zheng  pei
Abstract:kV GIS substation of Shajiao B power station is the power transfering center of Shajiao power generating base. It holds the balance of Guangdong province power network. On the basic of introducing the main equipments of the GIS substation, this paper investigates the equipment faults in nearly several years, discusses the aging inevitability of the equipments, summarizes the conditions and results of routine detecting and tests, and puts forward the necessary operation surpervising instruments and managing steps, and the importance for safety operation and maintenance.