Analysis of heat transfer of loop heat pipe used to cool high power LED
Authors:XiangYou Lu  ZeZhao Hua  MeiJing Liu  YuanXia Cheng
Affiliation:(1) School of Energy and Power Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, China
Abstract:A novel loop heat pipe (LHP) cooling device for high power LED is developed. The thermal capabilities, including startup performance, temperature uniformity and thermal resistance of the loop heat pipe under different heat loads and incline angles have been investigated experimentally. The obtained results indicate that the thermal resistance of the heat pipe heat sink is in the range of 0.19–3.1 K/W, the temperature uniformity in the evaporator is controlled within 1.5°C, and the junction temperature of high power LED can be controlled steadily under 100°C for a heat load of 100 W.
Keywords:
本文献已被 SpringerLink 等数据库收录!