Abstract:This paper presents a method to calculate the average efficiency from the turbine shaft to the grid in wind energy converters. The average efficiency of three 500 kW systems are compared. The systems are: a conventional grid-connected four-pole induction generator equipped with a gear, a variable-speed synchronous generator equipped with a gear and a frequency converter, and a directly driven variable-speed generator equipped with a frequency converter. In this paper it is shown that a variable-speed generator system can be almost as efficient as one for constant speed, although it has much higher losses at rated load. The increased turbine efficiency that variable speed leads to has not been included in this paper. It is also found that a directly driven generator can be more efficient than a conventional four-pole generator equipped with a gear