Cable insulation density profile determined from ultrasonicvelocity measurements |
| |
Authors: | Piche L. Pelissou S. Crine J.-P. |
| |
Affiliation: | Nat. Res. Council of Canada, Boucherville, Que. ; |
| |
Abstract: | Density results obtained on the same cable sample with a column and from ultrasonic measurements are reported. A calibration curve relating ultrasonic velocity and cable insulation density is given for PE and crosslinked PE (XLPE) cables. The limits and advantages of deducing density profiles of cable insulation using a focused, ultrasound beam rather than the more time-consuming column measurements are discussed |
| |
Keywords: | |
|
|