660MW超超临界锅炉再热蒸汽欠温分析与处理方案 |
| |
引用本文: | 王宏生,王帅,吕春华.660MW超超临界锅炉再热蒸汽欠温分析与处理方案[J].锅炉制造,2020(3):18-20. |
| |
作者姓名: | 王宏生 王帅 吕春华 |
| |
作者单位: | 高效清洁燃煤电站锅炉国家重点实验室(哈尔滨锅炉厂有限责任公司);哈尔滨锅炉厂有限责任公司 |
| |
摘 要: | 国内火电机组引进的660MW超超临界锅炉技术,锅炉整体运行效果良好。但近几年,部分660MW超超临界电厂反馈存在再热蒸汽欠温问题,再热蒸汽汽温达不到额定值,低负荷工况下该问题更为明显,造成锅炉及机组效率偏低,对电厂的经济效益造成极大影响。
|
关 键 词: | 欠温 低温再热器 温度 改造 |
Analysisand Treatment Scheme of the Insufficient Reheater Temperature of the 660MW Ultra Super-Critical Boiler |
| |
Affiliation: | (State Key Laboratory of Efficient and Clean Coal-fired Utility Boilers(Harbin Boiler Company Limited),Harbin 150046,China;Harbin Boiler Company Limited,Harbin 150046,China) |
| |
Abstract: | The domesticthermal Power plant applied imported 660MW ultra super-critical boilertechnologyoperates well.However in recent years,some 660MW ultra super-critical plant exists the insufficient reheater temperatureproblem,the reheater temperature couldn*t reach to rated value.It is more obvious under low load conditions.It results to the low boiler efficiency and great influence on the economic benefit. |
| |
Keywords: | insufficient temperature low temperature reheater temperature retrofit |
本文献已被 CNKI 维普 等数据库收录! |
|