摘    要:介绍HOWDEN VNT型固定密封空气预热器的设计特点,如固定式密封系统、双重密封、驱动系统和轴承等。对安装、调试过程中所遇问题进行了分析,并提出相应的解决办法。

关 键 词:锅炉 空气预热器 特点 安装 调试 VNT型 电厂
文章编号:1002-3364(2001)03-0030-03
修稿时间:2000-09-29

THE FEATURES OF AIRPREHEATER USED IN THE SECOND-PHASE PROJECT OF HUANENG FUZHOU POWER PLANT AND SOLUTIONS OFPROBLEMS OCCURED IN THE PROCESS OF ITS INSTALLATION AND DEBUGGING
SHOU Bing. THE FEATURES OF AIRPREHEATER USED IN THE SECOND-PHASE PROJECT OF HUANENG FUZHOU POWER PLANT AND SOLUTIONS OFPROBLEMS OCCURED IN THE PROCESS OF ITS INSTALLATION AND DEBUGGING[J]. Thermal Power Generation, 2001, 30(3): 30-32
Authors:SHOU Bing
Abstract:The design features of HOWDEN VNT type stationary sealed air preheater, such as stationary seal system, double seals, driven system and bearings etc. are described. The problems encontered in the process of installation and debugging are analyzed, and appropriate measures to solve relevant problems have been put forward as well.