首页 | 本学科首页   官方微博 | 高级检索  
     

基于MEMS技术的SU-8胶被动微阀片的设计与研制
引用本文:耿照新,崔大付,马小玲. 基于MEMS技术的SU-8胶被动微阀片的设计与研制[J]. 纳米技术与精密工程, 2008, 6(5): 343-348
作者姓名:耿照新  崔大付  马小玲
作者单位:1. 中央民族大学信息工程学院,北京,100081;中国科学院电子学研究所传感技术国家重点实验室,北京,100080;北京大学微电子研究院微米/纳米加工技术国家重点实验室,北京100871
2. 中国科学院电子学研究所传感技术国家重点实验室,北京,100080
3. 中央民族大学信息工程学院,北京,100081
基金项目:国家自然科学基金,国家自然科学基金,国家自然科学基金 
摘    要:为解决微流体在微流控芯片上的单向流动,进而实现生化反应的片上系统,采用微机电系统(MEMS)技术加工出SU-8胶微型阀片.SU-8胶阀片具有弹性模量和弹性常数低、开启压力小、反向泄漏小、易于加工等特点.从理论上分析了不同厚度(10μm,15μm,20μm,25μm)的微型阀片在不同压力作用下的挠度和应力分布,在相同尺寸和压力下,SU-8微阀片的挠度与传统的硅阀片的挠度相比要大10倍左右.讨论了有阻尼作用下的谐振频率以及过流特性。可知阀臂和阀座的尺寸是影响阀片性能的主要因素.给出了加工工艺,测试了阀片的正反向过流性能,以水作为工作物质,得到3种厚度阀片的过流曲线,其最大正向流速达到7000μL/min.

关 键 词:微机电系统  微阀  有限元  SU-8

Design and Development of SU-8 Check Microvalve Based on MEMS Technique
GENG Zhao-xin,CUI Da-fu,MA Xiao-ling. Design and Development of SU-8 Check Microvalve Based on MEMS Technique[J]. Nanotechnology and Precision Engineering, 2008, 6(5): 343-348
Authors:GENG Zhao-xin  CUI Da-fu  MA Xiao-ling
Affiliation:GENG Zhao-xin, CUI Da-fu, MA Xiao-ling (1. School of Information Engineering, Central University for Nationalities, Beijing 100081, China; 2. State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100080, China; 3. National Key Laboratory of Nano/Micro Fabrication Technology, Institute of Microelectronics, Peking University, Beijing 100871, China)
Abstract:The SU-8 microvalve was fabricated by micro electro mechanical systems ( MEMS ) technique to solve one of stumbling blocks for liquid to flow in one way and lab on chip to miniaturize successfully. There exist some advantages such as low Young modulus and elastic constant, little turn-on pressure, low reverse leakage, fabrication easy and so on. Displacement and stress of microvalve with four thicknesses (10μm, 15μm, 20 μm and 25μm ) were discussed theoretically under different pressures. The displacement of SU-8 microvalve is 10 times greater than that of silicon microvalve with the same structure and pressure. Flow characteristics and resonance frequency were investigated under condition that microvalve work in the air and the damping environments. The performance of microvalve is influenced remarkably by dimension of microvalve's structure. Forward and backward flow characteristics were tested by experiment and fabrication processes were presented. The flow curves of three thicknesses of microvalve were achieved under different forward and backward pressure difference when using water as working media, and the maximal forward flow rate reached 7 000μL/min.
Keywords:SU-8
本文献已被 维普 万方数据 等数据库收录!