摘    要:根据长江流域高温高湿的气候条件,构建了两级蒸发冷却与溶液除湿相结合的复合空调系统。介绍了复合空调系统的流程,根据该地区的气候条件和相关的空调设计参数,比较了复合空调系统与一次回风空调系统的能耗。在设计工况下,复合空调系统的能效比为2.6,相比于一次回风空调系统的节能率为47.2%。

关 键 词:蒸发冷却  溶液除湿  复合空调系统  长江流域

Application of Complex Liquid Desiccant Evaporative Cooling Air-conditioning System
LU Jun,LIU Yuxi. Application of Complex Liquid Desiccant Evaporative Cooling Air-conditioning System[J]. Gas & Heat, 2012, 0(4): 26-30
Authors:LU Jun  LIU Yuxi
Affiliation:LU Jun, LIU Yuxi
Abstract:According to the high temperature and humidity climate in Yangtze River basin, a com- plex air-conditioning system with two-stage evaporative cooling and liquid desiccant is constructed. The process of the complex air-conditioning system is introduced. The energy consumptions of the complex air-conditioning system and the primary return air-conditioning system are compared according to the re- gional climate condition and the complex air-conditioning design parameters. The energy efficiency ratio of the complex air-conditioning system is 2.6, and its energy saving rate is 47.2% compared with the primary return air-conditioning system under the design condition.