首页 | 本学科首页   官方微博 | 高级检索  
     

洪门水电站主坝坝基F_(11)断层运行性态分析和评价
引用本文:郭文泉,江桂荣.洪门水电站主坝坝基F_(11)断层运行性态分析和评价[J].大坝与安全,2008(2):37-40.
作者姓名:郭文泉  江桂荣
作者单位:江西三和洪门水力发电厂,江西,鹰潭,335000
摘    要:对洪门水电站主坝坝基F11断层测压管资料从水位、坡降、位势、绳套图等方面进行了分析,结果表明帷幕防渗作用在减退,F11断层已受到冲蚀,运行性态正在逐步恶化,并提出应尽早进行补强灌浆的处理措施,保障大坝安全运行.

关 键 词:洪门水电站  断层  运行性态  分析  评价  洪门水电站  主坝  坝基  断层  安全运行  性态分析  评价  foundation  fault  analysis  大坝  保障  处理措施  补强灌浆  运行性态  冲蚀  减退  防渗作用  结果  绳套

Performance analysis on the fault F_(11) of Hongmen main dam foundation
GUO Wen-quan,JIANG Gui-rong.Performance analysis on the fault F_(11) of Hongmen main dam foundation[J].Large Dam & Safety,2008(2):37-40.
Authors:GUO Wen-quan  JIANG Gui-rong
Abstract:This paper analysed the measured data by piezometer tubes at the main dam foundation fault F11 of Hongmen hydropower station in aspects such as water level, gradient, potential, rope kit picture and so on, which indicated that the effect of anti-seepage curtain was declined, the F11 fault had been in erosion and its operation performance was deteriorated gradually. So that the paper put forward the advice that reinforcement grouting as soon as possible should be adopted to ensure dam safety.
Keywords:Hongmen hydropower station  fault  operation performance  analysis  appraisal  