Abstract: | In this paper a PID controller is proposed to ensure the fuel ethanol composition at desired value, above 92.5°INPM, at the same time as saving energy through the minimal use of reboiler power. Due to the fact that composition analyzers are expensive and have a high response time, an inference model was developed in which the product composition is inferred from the product temperature and thermodynamics equations, enabling the monitoring and the indirect control a posteriori of this variable. In addition, the inference of composition allows defining the reference value of the product temperature, which ensures the fuel ethanol production at the desired composition. |