首页 | 本学科首页   官方微博 | 高级检索  
     

引风机动叶调整故障原因分析及优化方案研究
引用本文:彭博伟.引风机动叶调整故障原因分析及优化方案研究[J].上海电力学院学报,2016,32(5):499-503.
作者姓名:彭博伟
作者单位:安徽华电六安发电有限公司 生产技术部
摘    要:以某厂动调轴流引风机为研究对象,介绍了一起因液压缸故障引起机组跳闸的事故,并分析了故障原因,主要有两点:动叶指令函数死区过大;RB保护动作无法触发.针对以上原因,提出了一种对风机状态参数信号进行综合判断的优化方案,对引风机的故障进行融合处理,并触发引风机跳闸,再通过RB保护动作,从而有效避免了机组主燃料跳闸,提高了机组安全运行性能.

关 键 词:引风机  动叶指令  RB保护  机组MFT
收稿时间:2016/6/30 0:00:00

Cause Analysis on Faults of Rotating Blades Regulation of Induced Draft Fan and Optimization Research
PENG Bowei.Cause Analysis on Faults of Rotating Blades Regulation of Induced Draft Fan and Optimization Research[J].Journal of Shanghai University of Electric Power,2016,32(5):499-503.
Authors:PENG Bowei
Affiliation:Production Technology Departmant, Anhui Huadian Lu''an Power Plant, Lu''an 237126, China
Abstract:Induced draft fan of some power plant is taken as a research object,and an accident of unit trip with fault of hydraulic actuator is introduced.By means of analysis,it is discovered that there are two main causes for the fault:oversized instruction function dead of rotating blades and RB protection is not triggered.Relevant optimization researches are adopted in allusion to the above causes.It makes fusion process for the fault of the induced draft fan,and triggers trip of the induced draft fan through movement of RB protection.Accordingly,it effectively prevents the unit MFT and improves the safe operation of unit performance.
Keywords:induced draft fan  rotating blades instruction  RB protection  unit MFT
本文献已被 CNKI 等数据库收录!
点击此处可从《上海电力学院学报》浏览原始摘要信息
点击此处可从《上海电力学院学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号