水轮发电机磁极线圈匝间短路检查及处理
引用本文:朱洪雷. 水轮发电机磁极线圈匝间短路检查及处理[J]. 防爆电机, 2012, 47(3): 48-50
作者姓名:朱洪雷
作者单位:哈尔滨电机厂有限责任公司,黑龙江哈尔滨,150040
摘    要:主要就各水电站水轮发电机组正常运行中,磁极匝间绝缘损坏事故所占比重较大,往往成为严重安全隐患.因此,采用快速正确的方法,对转子匝间短路故障进行预防、检查及处理至关重要.通过实例简述转子磁极线圈匝间短路的几种常见情况及处理方法,供借鉴.

关 键 词:转子  绕组  线圈  匝间短路

Inspection and Treatment of Interturn Short Circuit of Hydraulic Turbine Generator Magnetic Pole Coils
Zhu Honglei. Inspection and Treatment of Interturn Short Circuit of Hydraulic Turbine Generator Magnetic Pole Coils[J]. Explosion-proof Electric Machine, 2012, 47(3): 48-50
Authors:Zhu Honglei
Affiliation:Zhu Honglei
Abstract:This paper puts forward that the interturn insulation damage failure of magnetic pole coil accounts for a larger percentage in failures of hydraulic turbine generator sets of various water power stations at normal operation, and it often becomes serious safety hazard. Therefore, it is crucial for prevention, inspection and treatment of rotor interturn short-circuit failure by a quick and correct method. Several common interturn short-circuit situations and treatment methods of rotor magnetic pole coils are briefly described here by practical example. It provides some reference.
Keywords:Rotor  winding  coil  interturn short circuit