摘    要:中压安注注射管线的平均压降系数(L/D)。对于核电站的安全非常重要,文章计算了某核电站中压安注系统的(L/D)。以及其误差A(L/D)m,结果表明(L,D)m=586.40,(L/D)m+A(L/D)m。608.10,(L/D)m—A(L/D)m=564.70,压降系数及误差符合核电相关的安全准则要求,该系统可以实现其安全功能。

关 键 词:中压安注系统  压降系数  误差  计算

Calculation of Pressure Drop Coefficient and Error in the Accumulator Injection Lines
Li Hui.Calculation of Pressure Drop Coefficient and Error in the Accumulator Injection Lines[J].Guangdong Chemical Industry,2011,38(2):221-222.
Authors:Li Hui
Affiliation:Li Hui(Commissioning Center,China Nuclear Power Engineering Co.,Ltd.,Zhengzhou 450052,China)
Abstract:Average pressure drop coefficient(L/D)m in the accumulator injection lines is of consequence for nuclear power stations.(L/D)m and measurement error Δ(L/D)m were calculated in the paper.The result showed that(L/D)m = 586.40,(L/D)m +Δ(L/D)m = 608.10 and(L/D)m-Δ(L/D)m = 564.70.The pressure drop coefficient and error satisfy the safety criteria of the nuclear power station,which ensure the realization of the safety function of the accumulator system.