首页 | 本学科首页   官方微博 | 高级检索  
     

主动调相型脉管制冷机数值模拟与实验研究
引用本文:周志坡,蒋珍华,朱海峰,杨森,张安阔,吴亦农.主动调相型脉管制冷机数值模拟与实验研究[J].低温工程,2017(3).
作者姓名:周志坡  蒋珍华  朱海峰  杨森  张安阔  吴亦农
作者单位:1. 中国科学院上海技术物理研究所 上海200083;中国科学院大学 北京 100049;2. 中国科学院上海技术物理研究所 上海200083
摘    要:设计了一台主动调相型斯特林脉管制冷机,采用线性压缩机作为脉管制冷机主动调相控制器(APC),连接于冷指热端出口。通过控制调相压缩机与驱动压缩机(PWG)间的位移相位角实现主动调相,从而调节质量流和压力波之间的相位关系,优化制冷性能。利用模拟软件进行数值模拟并进行实验研究。研究结果表明,定输入功下APC与PWG位移相位角为-110°及扫气容积比(PWG扫气容积/APC扫气容积)2.98时,无负载制冷温度最低,同时比卡诺效率最高,能够达到原惯性管型脉管制冷机同样的效率。

关 键 词:脉管制冷机  主动调相  数值模拟  实验研究

Experimental research and simulation of Stirling type pulse tube refrigerator with an active phase control
Zhou Zhipo,Jiang Zhenhua,Zhu Haifeng,Yang Sen,Zhang Ankuo,Wu Yinong.Experimental research and simulation of Stirling type pulse tube refrigerator with an active phase control[J].Cryogenics,2017(3).
Authors:Zhou Zhipo  Jiang Zhenhua  Zhu Haifeng  Yang Sen  Zhang Ankuo  Wu Yinong
Abstract:A Stirling type pulse tube refrigerator(PTC) with an active phase control was design.An electrically driven and mechanically damped linear compressor,which is directly connected to the warm end of the pulse tube by using a connecting tube,is used as the active phase controller (APC) instead of using inertance and buffer as a phasor.Stirling type active phase control pulse tube refrigerator is easy to control the electric input power and the displacement phase angle between APC and pressure wave generator (PWG),which helps to control the phase angle between the mass flow and the pressure so as to optimize the performance of the pulse tube refrigerator.One-dimensional software was used to simulate the Stirling type pulse tube refrigerator with APC.And the Stirling type pulse tube refrigerator with APC has been experimentally investigated.The study turns out when the electric input power is constant,the displacement phase angle between APC and PWG is-110 degree and the sweep volume ratio (the PWG sweep volume / the APC volume)is 2.98,the cold end temperature with no load can get lowest and the relative Carnot efficiency can reach highest,and the efficiency is the same as that of the Stirling type pulse tube refrigerator with an inertance tube.
Keywords:pulse tube refrigerator  active phase control  numerical model  experiment
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号