Optimal FIR filter for suppression of power line frequency component
Authors:V. S. Stojanovic  M. S. Stankovic
Affiliation:1. Department of Electrical Engineering , National Yunlin University of Science and Technology , Yunlin, 640, Taiwan lin_borren@yahoo.com;3. Graduate School of Engineering Science and Technology , National Yunlin University of Science and Technology , Yunlin, 640, Taiwan
Abstract:In this paper a design technique for multiband FIR filter for DC and power line frequency component suppression is described. The digital filter has a linear phase characteristic and equiripple amplitude characteristic in the passband. The amplitude characteristic of this filter satisfies the alternation theorem and consequently has the lowest complexity in obtaining a prescribed maximum deviation in the passband and the fastest possible rate of attenuation near the cutoff frequency. In this sense this filter is optimal. Closed-form expressions for direct calculation of filter coefficients, cutoff frequency and maximal passband attenuation are derived.
Keywords:PWM  SMPS  power conversion  converters  ZVS