首页 | 本学科首页   官方微博 | 高级检索  
     

轴压比对方钢管混凝土柱受力性能的影响
引用本文:王鑫,南喜涛,苏永. 轴压比对方钢管混凝土柱受力性能的影响[J]. 山西建筑, 2009, 35(15): 3-5
作者姓名:王鑫  南喜涛  苏永
作者单位:天水师范学院工学院,甘肃,天水,741001
摘    要:以BASE试件为基础设计了3个具有不同轴压比的ZY试件并进行了非线性有限元分析,研究表明柱轴压比不能太大,把柱的轴压比控制在0.5以内为佳,在方钢管的底部和底角部存在应力集中现象,对方钢管的底部应加大刚度,柱底角部应加强施焊。

关 键 词:方钢管混凝土柱  轴压比  有限元

The effect of axial load ratio on behavior of square concrete-filled steel tubular column
WANG Xin,NAN Xi-tao,SUN Yong. The effect of axial load ratio on behavior of square concrete-filled steel tubular column[J]. Shanxi Architecture, 2009, 35(15): 3-5
Authors:WANG Xin  NAN Xi-tao  SUN Yong
Affiliation:WANG Xin NAN Xi-tao SU Yong
Abstract:Basing on BASE,the auther designs three ZY square concrete-filled steel tubular columns and analyses them by nonlinear finite element,by research it showes that the axial load ratio shouldn't be too large and control axial load ratio which is smaller than 0.5.The stress poll will appear in the bottom and corner of column,therefore the stiffness of bottom of column must be enhanced,the corner of column must be welded greatly.
Keywords:square concrete-filled steel tubular column  axial load ratio  finite element  
本文献已被 CNKI 维普 万方数据 等数据库收录!