首页 | 本学科首页   官方微博 | 高级检索  
     

某厂房火灾后结构安全鉴定及加固处理分析
引用本文:尹国超,吴启红,余智强.某厂房火灾后结构安全鉴定及加固处理分析[J].山西建筑,2010,36(20):58-60.
作者姓名:尹国超  吴启红  余智强
作者单位:1. 广东东莞市建筑科学研究所,广东,东莞,523112
2. 四川成都大学城乡建设学院,四川,成都,610106
3. 广东东莞市大业建筑咨询有限公司,广东,东莞,523112
摘    要:以某厂房火灾后结构安全鉴定及加固处理为例,通过火灾现场勘查、构件及混凝土强度检测、计算分析等手段,对受损混凝土构件进行安全性评级,并提出相应的加固处理建议,对类似的火灾后厂房结构安全鉴定有一定的指导作用。

关 键 词:火灾  结构鉴定  加固处理

On structural safety evaluation of some workshop after fire accident and its intensification treatment analysis
YIN Guo-chao,WU Qi-hong,YU Zhi-qiang.On structural safety evaluation of some workshop after fire accident and its intensification treatment analysis[J].Shanxi Architecture,2010,36(20):58-60.
Authors:YIN Guo-chao  WU Qi-hong  YU Zhi-qiang
Affiliation:YIN Guo-chao WU Qi-hong YU Zhi-qiang
Abstract:By taking the structural safety evaluation of some workshop after fire accidents and its intensification treatment as an example, the paper according to the measures including the field investigation, the tests on the components and concrete strength and the calculation analysis, undertakes the safety evaluation degree for the damaged concrete components, and points respective intensification treatment suggestions, so as to have the direction for the similar workshop structure after fire accidents.
Keywords:fire accidents  structural evaluation  intensification treatment