首页 | 本学科首页   官方微博 | 高级检索  
     

离子膜电解槽电压升高原因剖析
引用本文:刘存玉.离子膜电解槽电压升高原因剖析[J].中国氯碱,2011(12):18-20.
作者姓名:刘存玉
作者单位:淄博职业学院,山东淄博,255013
摘    要:结合出现电压升高故障的离子膜电解槽实例。对影响离子膜电解槽槽电压升高的因素进行了分析并提出了预防措施。

关 键 词:离子膜  电解槽  电压升高  原因

Anatomy of reasons for cell voltage increase of chloro-alkali ion membrane electrolyser
LIU Cun-yu.Anatomy of reasons for cell voltage increase of chloro-alkali ion membrane electrolyser[J].China Chlor-Alkali,2011(12):18-20.
Authors:LIU Cun-yu
Affiliation:LIU Cun-yu (Zibo Vocational Institute, Zibo 255013, China)
Abstract:With an ion membrane elehrolyser having abnormal cell voltage increase during operation as an example, a number of reasons for cell voltage increase were analyzed, and preventive measures that should be take were put forward.
Keywords:ion membrane  electrolyser  cell voltage increase  reason