首页 | 本学科首页   官方微博 | 高级检索  
     


Diameter measuring technique based on capacitive probe for deep hole or oblique hole monitoring
Affiliation:1. School of Mechanical Engineering, University of Jinan, Jinan 250022, China;2. School of Computer Science and Technology, Tianjin University, Tianjin 300072, China;1. Department of Mechanical Engineering, National Chung Hsing University, Taichung 402, Taiwan, ROC;2. Institute of Electro-Optical and Materials Science, National Formosa University, Yulin, Taiwan, ROC;1. Zhejiang Industry Polytechnic College, Shaoxing 312000, China;2. School of Aeronautics and Astronautics, Zhejiang University, 310027 Hangzhou, China
Abstract:A deep hole or oblique hole diameter measuring system was introduced, a cylindrical capacitive probe with effective measurement electrode was adopted to measure the diameter by measuring the clearance between the probe electrode and the measured hole, and it has no measurement force by measuring in non-contact mode. And then, we obtain the precision diameter measurement system for straight holes. By using the measurement system in oblique hole, we can see that with the increase in the hole depth, the measurement results are basically approaching stable value.
Keywords:Diameter measurement  Deep hole  Blind hole  Oblique hole  Capacitive sensing probe
本文献已被 ScienceDirect 等数据库收录!